Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What does substation
operator do in
substation?

Answer Posted / dhavalb

first maintance is required in substation.check the all the reading in control room.A Substation Operator’s is to inspect, operate, and maintain electrical substations, which contain equipment that transforms electricity from one voltage to another so that it can be safely used by customers.

Put another way: An electrical grid is like a relay race. The starting line is the power plant and the finish line is the customer’s home or business. In between, the baton — electricity — is passed between hands several times, which helps it travel farther, faster.

Within an electrical distribution system, the points at which the baton is passed are the electrical substations, while the relay runner who does the passing is the Substation Operator.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what shoud be strength and weakness to impress interviewer????????

2022


Is a d.c.compound motor is use as a booster? how?

2084


design of IGBT firing circuit for 11KV

2573


What are the roles and responsibilities of electrical engineer in cement plant

1968


Describe the colour rendering properties of i) tungsten filament lamps ii) tubular fluorescent lamp

3077


Why we do 2 types of earthing on transformer (ie:)body earthing & neutral earthing , what is function. I am going to install a oo kva transformer & 380 kva dg set what should the earthing value?

1096


along with technical test papers

1554


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1739


how ups works ? various parts of ups and working principle

1900


can someone explain that how the speed of the protection system affects the fault level calculation?

2014


What is meant by short-pitched winding?

1130


If we impress a dc voltage of 230 V on an unloaded 230 V, 50 Hz transformer it wi A give high secondary voltage B burn out C give secondary voltage as per K D none of these

1954


How To Convert Apparent Into Real Power Without Knowing Reactive Power?

1718