why transmission line 11Kv OR 33KV,66Kv not in 10kv 20kv?
Answer Posted / maheswara reddy modugula
Why transmission line 11KV OR 33KV, 66KV not in 10KV 20KV?
1•The miss concept is Line voltage is in multiple of 11 due to Form Factor. The form factor of an alternating current waveform (signal) is the ratio of the RMS (Root Mean Square) value to the average value (mathematical mean of absolute values of all points on the waveform). In case of a sinusoidal wave, the form factor is 1.11.
2.The Main reason is something historical. In olden days when the electricity becomes popular, the people had a misconception that in the transmission line there would be a voltage loss of around 10%. So in order to get 100 at the load point they started sending 110 from supply side. This is the reason. It has nothing to do with form factor (1.11).
3•Nowadays that thought has changed and we are using 400 V instead of 440 V, or 230 V instead of 220 V.
4•Also alternators are now available with terminal voltages from 10.5 kV to 15.5 kV so generation in multiples of 11 does not arise. Now a days when, we have voltage correction systems, power factor improving capacitors, which can boost/correct voltage to desired level, we are using the exact voltages like 400KV in spite of 444KV
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
what is the relative size of single and three phase?
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
What is the reason for using a GE G101 MCB in place of an EP102 MCB if both are capable of AC circuit protection?
what is the transformer rush current?
do we use neutral grounding for resistive balanced load? if we use what happen?
what is JE exam?
What is called limb of a transformer?
What is industrial plc
How to select a cable size for particular load?
sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)
What is relation between mu(nought) and epsilon(nought)?
suri transmission
how to ctrl motor by use of ac or dc drive.plz explain evdintly
can we do the star delta connection of capacitor for 3- phase motor starter.
How Diesel Generator start ?