Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is CRGO Transformers?

Answer Posted / bhanu

What is fuse material ? Mention different types of fuse material.
Name - Bhanu
Electrical engineering
3rd semester
K.L POLYTECHNIC , ROORKEE , HARIDWAR

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to meas-our losses for L.T & H.T

2170


in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain

1857


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1788


we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.

2066


Mention what are the types of semi-conductors?

1217


why high speed tripping relay will be used in tripping circuit why not normal relay

1371


what is meant by carrier aided trip protection in transmission line

3927


how to select rating of HT Panel

1457


what is meant by residual over voltage & residual earth fault ?

8923


why i can not use thimble on capacitor duty contactor

1358


what is mean by NPS (Negative phase sequence)fault? what is the difference between EFR & OCR faults?

2373


Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2509


How to calculate the sag of OPGW during stringing???

2586


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1683


Dear friends I want to design busbar for1600 kva transformer(i.e2100 amps) what are all the factors to be considered before selectinga busbar what are all the standard sizes of busbars what is the formula for finding current of copper and aluminium busbar

1903