Why synchronous motor runs at a fixed speed?
what is the name of that fixed speed?
Answer Posted / avinash
Synchronous speed is the speed at which the stator field magnetisation is rotating, which depends on supply frequency and number of poles.
Rotor of the synchronous motor is a magnet that can LOCK with the rotating stator field and rotate at synchronous speed.
Rotor has to be externally brought to synchronous speed of the stator then it will continue at synchronous speed provided load is within limit.
Synchronous motor will rotate either at synchronous speed or come to stop.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Explain Circuit Breaker Trip Characteristics in detail.
What are the advantages of autotransformer?
What is the settings of distance protection relay in 400 kv line
what is earth resistance? how to measured? and give values at power station and mcc area?
If a 3 phase induction motor is in off condition in the conveyor and rotor of the motor keeps moving with the conveyor than the resistance of windings of motor varies. why is it so ??
can we start slipring motor on star delta like we start induction motor ? if yes where will we connect ?
What are the three types of compensators?
why fractional pitch winding generally used in alternators?
whati s the sludge current in ups
Give the topology of current amplifier with current shunt feedback?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
is it possible to turn on the single phase star delta on delay timer using 24 v dc ?
Which device is used for the source of emission of electrons in a crt?
To prove the capacity of a 10MVA transforemr with 6.5% impedance by a short circuit test how much power is needed to inject an impedance voltage if we have to arrive for its rated current?