what will happen when excitation of a synchronous machine
is suddenly reduce to zero when it is running at full
load..??

Answer Posted / vidhya

if its a salient pole synchronous generator whose synchronising power is P=E*v/x+v2/2[1/Xq-1/Xd], where Xq and Xd are quadrature axis reactance and direct axis reactance respectively as can be seen the first term is dependent on excitation (E=field emf) this term will be =0 but the 2nd term does not depend on E hence the synchronous generator (salint pole) will keep supply power but this power is reluctance power and thus the synchronous gen will act as reluctance generator.many might think if E=0 how v(terminal voltage ) is not=0.well thats bcoz the output of generator is connected to infinite bus whose terminal voltage is always maintained at V.

Is This Answer Correct ?    15 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

IF DISTANCE IS 100METERS B/W AMP.METER AND CURRENT TRANSFORMER WHAT WILL BE AFFECT IN ACCURACY .METER CAN SHOWING ACCURATE CURRENT OR NOT IF NOT WHAT CAN I DO TO GET 100% ACCURACY.

1405


sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in

1535


what is meaning of bus riser

1935


Why saturation region slowly shifted in the left side?

1434


What is Phase to Phase clearance for 800V System Operating Voltage as per IEC61439

525






What is critical disruptive voltage?

822


Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.

1466


which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?

1492


when will be the iocl interview results i faced interview on 8th september 2008 iam from electrical branch i faced interview for the post of electrical engineer??????????????????????//

1578


I need model question papers for RRB section engineer Chennai... Please send to my E-mail Id:- maitheerainbow@gmail.com

1462


how we can calcultae the short circuit level for bus bar

1714


For a spring controlled governer the relation F = ar+b (F is the controlling force, r is the radius of rotation a and b are constants), indicates that the governer is

713


Write the force balance equation of m ideal mass element.

698


how we can do the insulation on secondary of ct explain and so that tan delta will within limit

1438


What are the protections for safe running of electric generator?

1703