why earth hole size is biggest in plug point?
Answer Posted / neha
as we know that the area of cross section is inversely proportional to the area or R=rho(l/a)....so to decrease the resistance there is a large hole of earth in plug point as it is connected to zero potential (earth) for safety purpose
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Determine the BTU size of an aircon for 20 sq metre room
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
What is PQA???Applications........
how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.
how make megger test for control cable like 12c x 1.5mm and what it apply voltage and test timing details.
Is there any standard guidelines/Criteria to design NGR/NGT.?
What is Traction? 1KVA Alternator, How much urrent taken?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What is the minimum distance to be maintained in between HT panel and LT panel and Instrument panel as per IEC and NEC standards?
What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?
xpression 'document.FrmQF.myemail' [
What happen to the transformer if the OLTC frequently used for lower and raise occured 50times daily?
The Howland current source produces a A Unidirectional floating load current B Bidirectional single-ended load current C Unidirectional single-ended load current D Bidirectional floating load current
How to test the Secure Elite 440 Multi function meter working condition.