Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What will happen if the rotor of an induction motor is fed
from a 3 phase supply and the stator short circuited ?

Answer Posted / manas ghosh

It is
just like using the secondary of a transformer as primary. In this case the effective load depending on the value of rotational speed, which is r(1/s - 1) will be on the stator side. so, here 'r' is the actual stator resistance. Here supply side(rotor) acts as primary and stator acts as secondary. All other quantities like silp,Ns remain same but the definition of silp is not the same as in the case of stator side supply.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Under wat condition statcom operates as an inductor for the transmission line?

1937


what is the use of Auto re-closer?

2147


What is the technical difference between On delay timer and a Star delta timer?

1617


why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?

2148


What is the use of lag compensator?

1239


In convertor can we use rectifier thyristor in place of invertor thyristor with explain.

1820


What will happend if given Vfd out put to step up transformer

1821


what is the k var ratting of 1250kva

2093


what is formula for calculate thermal overload in new numiricalrelay( not in bimetal relay)?

2313


What is the estimated total hydropower potential of india?

1138


could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?

2038


I want to merge a cable..in between two metering Cubicals which contains CT's and PT's and Energy meter..before taking merger..what are the common things required?

1661


what is tri state logic gate

2204


at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)

1911


Meter p.t. ratio= 3×230/400 , c.t.ratio = 3×1 (2) A what is m.f.

1754