What is the inside of ACB & VCB & SF6 breaker's pls tell me about this
Answer Posted / sanjayjssate
Above answer is correct , but acb is used for voltage less than 1100 v, vcb is used for voltage less than 33kv and sf6 breaker is used for voltage above 33 kv.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
How we calculate DC inducation moter Amp? Sir pls give me formula......
The screw thread commonly used for transmission of motion is one of the following types of threads
we have a lot of model of rectifier but thyristor rectifier is the most rectifier that use in power system. Do you know why this rectifier is used?
what are the main applications of transistor in non-linear region?
How to synchronization will be done between two DGs ?
Whether the vacuum contactor requires Short circuit protection?If No,why?
What is EMC filter in VVVF Drive ?
can mini-curcuit supply MIL-tested transformer !
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
What is the unit of attenuation?
How do we calculate transformer oil in liter from the rating of the transformer.
What is NGR . What is the purpose of 10 sec ,60 sec rating of NGR.
why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
How do u analyse protection fault when vcb tripping on load