Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

A concentric, counter-current heat exchanger is used to cool lubricating oil. Water is used as the coolant. The mass flow rate of oil into the heat exchanger is 0.1 kg / s = FO. For oil, the inlet temperature TIO = 100 degree Celsius and the outlet temperature TOO = 55 degree Celsius. For water, the inlet temperature TIW = 35 degree Celsius and the outlet temperature TOW = 42 degree Celsius. What is the mass flow rate of water in kg / s, FW needed to maintain these operating conditions? Constant for heat capacity of oil is CO = 2131 J /(kg K) and for water is CW = 4178 J /(kg K). Use the equation (FO)(CO)(TIO – TOO) = (FW)(CW)(TOW – TIW).

Answer Posted / kang chuen tat (malaysia - pen

Answer 16 : Rearranging the given equation, then FW = (FO)(CO)(TIO – TOO) / [ (CW)(TOW – TIW) ] = (0.1)(2131)(100 – 55) / [ (4178) (42 – 35) ] = 0.327891 kg / s. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i have done B.TECH in che.tech.and doing MBA . why you doing mba why u have not join any job.

2308


For what ration of Lengh/Dia. of tank (Jacketed tank), maximum heat transfer area is available?

2070


What is the largest application for surfactants?

1308


Why should a magnesium ribbon be cleaned before burning in air?

1138


Explain the use of gear pumps in motor?

1019


What is the best way to handle bend or turns in slurry piping systems?

1031


How can you control the ph level in our cooling water with respect to ammonia contamination?

1086


Why does catalytic converter used in an automobile?

1015


How instrument air is continually supplied in process plant?

1118


Explain the factors involved in designing kettle type reboiler?

1004


Explain the procedure to estimate the friction factor involved in heat exchanger tubes?

1095


is extractive distillationӞH

2192


design calculations for reactor

2633


MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)

2399


What is a good source of information for the design of pressure vessels?

1063