3phase 4 wire system is more reliable or 3 phase 3 wire systems?
Answer Posted / suraj chawardol
We should have clear concept regarding where 3 phase 3 wire system used and where 3 phase 4
Wire system used
1.3 phase 3 wire system= In India electrisity is generat at 11 or 33 kv.then it is step up with the help of tranformer. To transfer it from generation station to substation 3 phase 3 wire system is used. Then it is step down at substation or directly feed to application having such rating. Genarally 11 kv feeder are brought near to distrubution transformer near to load ( near to home genarally called DP). The input to distribition transformer is 11 kv feeder and output of transformer is 440 v , 3 ,phase 4 wire system. ie 3 phase R,Y,B and one neutral.
2. 3phase 4 wire system = the secondary side of transformer is star connected so line voltage become 1/sq root 3, ie near 240 v . Our home appliances are design to work at Approximataly 230 v ,50 hz so we need any one phase and neutal for single phase load .
3. Also for high power application we need 3 phase 3 wire system such as Induction motor.
4. Both the system have its own importance depending on applications.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is two point starter?
How to calculate capacitor bank size at a load 800kVA.
Which capacitor is preferred for high voltage and frequency?
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
I have done my m.tech in electrical engg discipline. Can any one please suggest me how should I prepare for getting into phd in iit or nit.How should I prepare for getting into lecturership
what is the value of combined earthing in general electrical circiut?
What is the permissible limit of shaft voltage for 6.6 KV motors ? Why? Is there any standard is available?
Why is the frequency not changed during transformation of electrical energy in a transformer?
What are the types of excitation system?
Explain what is electric traction? Explain few advantages of electric traction system?
ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH
what will be the effect if you were using different brands of outlets?
how to check avr of dg set of 125kva
in shunt clippers why a resistor is used in sereis with the input
Explain the role of a car driver as one of a feedback mechanism.