Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Motor running trough VFD, if voltage reduced speed will be?

Answer Posted / gennadiy

Yes, the voltage in the simpliest V/f control is decreased proportionally with the speed decreasing. V~f in linear V/f control and V~f*f in parabolic V/f control (for pumps and fans).

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.

1112


how cables go in and come out for distribution from the feeder pillar box?

2095


The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?

3684


how to test and calculat the head and discharge in borewell compressor

2164


What is meant by harmonic distortion?

1123


what will happen if OLR CT in all phases are short circuted

2199


what type of questions are asked and howmwny questions belong this catagory?

2123


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2723


Can u Explain about the electronic trivector meter and the use of data converters in them?

2371


what r the safety measures in UPS ? explain all?

2230


working function importance of mdc meter

2174


plz send me the placement interview question and answers of whizchip(technical and apttitude)..i have an interview in next.

4999


i am venkat i got gre 930(verbal 270 quanta 660) and my toefl score 105..here question is why u got less score in gre ? what i supposed to tell...any chance of rejection is there...my accadamics record is very good

2149


is this the formula of building wiring to get the main breaker.Watts/volts*.8%+higher motor*(25%)=ampere. yes or no or send the correct formula for building wiring.

1717


testing of Vector Group – YNaoD II

2942