Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between RCB,RCCB &RCBO?

Answer Posted / ashmal zadir

RCD is the group name for residual current protective devices.
RCCB is an RCD that fits in the breaker panel
RCBO has additional overload protection and also fits in the breaker panel. RCBOs were mainly designed to protect individual circuits inplace of an MCB. RCCB is used to protect many circuits with individual MCBs
I assume RCB is just another name for RCD. Here is a good link where i found the information.

http://www.cycloflow.com/2014/02/what-are-elcb-rccb-rcbo-and-rcds.html

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to build a network which step down 415v to 1v rms

2064


What should be the length of transmission line so that we can see/obtain the full sine wave of voltage??

1945


Why neutral point is consider as zero potential?

2711


WHAT WOULD BE THE FORMULA OF WIRE GAUGE FOR A FULL LOAD CURRENT

2418


HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?

2680


What is kirchoff ’s current law (kcl)?

1138


can we use engine degreaser for electrical motors?

1816


what is mean by descripiency relay? & wht is its ansi code?

3211


how to failure indution motor insulation & how to improve heat in motor insulation

1929


How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?

1867


we have provided 30 nos. relay contacts in panel.I want to know how do we do the numbering for the relay contacts as per any applicable standards

2053


xpression 'document.FrmQF.myemail' [

2062


What should be the amps for a MV fuses for transformer 630kVA 20(10)/0.4 kV

2103


how we can set the IDMT relay.

2266


We are planning to synchronized DG's with our captive plant in the event of black start of plant, but before sync we checked voltage of DG with our plant voltage and it varies from 5 V to 450 V. So in this condition how we can sync DG with plant ?

1716