Answer Posted / noufal p
Substation can be defined as an electrical apparatus which mainly changes some parameters of grid such as Voltage and Current
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is meant by motor startup supervision & motor load jam protection ?
What is the capacity of the Fastners 12mm?
What range of speed can you get with the field control method of speed control of d.c. Shunt motor?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Difference between rating factor of cable and derating factor of cable?
sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)
how to find number of run cable laying[LT side] for transformer & alternator secondary side? [above condition for getting output power transformer to main panel side] give the example.
Difference between control junction box (cjb) and power junction box(pjb)?
A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.
What type of a DC motor would you use for a lift?
in dc shunt motor if field winding is shorted then
can indirect loading be called as phantom loading?
how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.
Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT?
I am experienced with house and industrial wiring but I don't have any licence how can I apply an licence and which type of licence i can get i didn't complete deee just only experience