Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the use of excitation transformer in LAVT PANEL?

Answer Posted / sudarshan

excitation transformer is alternate to pmg in case of generator excitation,its rating is same as excitation required by generator.
in case of failure of pmg generator main main exciter can be excited through excitation transformer.

excitation trans----.
......main exciter.....rotor
pmg----------- .

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the use of iron core in a transformer?

1128


oil cooled transformer

2213


What is the Basic Difference bitween Long Shunt Connection and Short Shunt Connection in DC Generator?

2339


What are the two basic types of transformers?

1163


Which type of motor is used in trains, what is the rating of supply used explain working principal?

1283


i want to model paper for section engg.

1997


i have total 8 dg sets for synchronizing and 2 buscoupler,1 sectoin dg no 1,2,3,and 2 sectoin dg no 4,5,6,and last section dg no 7,8 ....if buscupler no 1 and 2 is off mode ..than dg no 1,2,3,will synchroniz of another dg sets?

1807


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2347


I PURCHASED A DEISEL GENARATOR SET OF AVR TYPE& RATING 125KVA BUT SOME TIMES THE OUTPUT VOLTAGE IS FLUCTUATING WHAT ARE THE PROBABLE REASONS GIVE ME

1827


how can we calculate the ratio of caustic soda and water in lrs.

5841


1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

2031


What is the formulae of Megger value for a A.C.Motor

2878


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2275


what is method for testing CT

2136


11 kv input, 66 kv input advantages

1386