Answer Posted / suraj kumar
Ground is for the Safety , i think Ground and earthing is same thing, and neutral is getting from star point of RYB phase for getting Single phase .
and make balance to each phase when connected with three phase.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Why squirrel cage motor can only use with low starting loads ?
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
What is an 86-P or an 86-A trip
why sielent pole is used only in hydro generators and not in turbo generators
In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com
What is the difference between UPS & inverter ? which UPS is better and whos got the edge ? what is the difference between & inverter ? which UPS is better and whos got the edge 12 V , 24 V , 36 V etc what are the advantages of 12 V, 24 V , 36 V etc and what are the disadvantages of 12 V, 24 V, 36 V etc thanks
i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula
What was the Dg set radiator and lube oil temperatures trip in ACB
why the frequency and voltage in india is 230v and 50HZ. when compared to USA say 110v and 60 HZ.
show the single line diagram of star delta starter with single phase preventer
state basic meaning of 'INDUSTIAL AUTOMATION'?
What is minimum permicible value of leackage current for LT Panle when applying voltage up to 3 KV for 5 Minuits?
WITCH CARDS IN USE IN FIRE CONTROL PANEL.