Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

When LP SURGE happening in compressor

Answer Posted / thomas

'Surging' is defined as 'A momentary back-flow' through the compressor from the discharge to the suction. This can occur when the mass flow of gas to the compressor falls below a critical level with a high pressure difference across the machine. When there is not enough gas to replace that being pushed forward, discharge gas will flow backwards through the compressor towards the suction side. This back-flow will tend to decrease the speed of rotation while the speed controller will try to maintain the correct speed. The gas flowing backward provides more volume to the suction side and the compressor picks up and begins to push gas forward again. The machine speed will tend to increase and the governor will again try to maintain the correct, set speed. All of this takes place very quickly; the backward and forward gas flow together with the speed control action causes rapid fluctuations in the flow and pressure of the system. This 'Surging' in the machine can be very damaging to the compressor and associated piping and equipment due to heavy vibrations set up in the system. Generally, if the suction flow drops too low, a 'Low-flow Trip' will shut down the machine. Also, surging can cause the machine to 'Overspeed' before the control system can react. This can also cause damage and is prevented by an 'Overspeed Trip Mechanism' which will again shut down the machine.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com

3157


model question paper of instrumentation for Jindal GET 2010.plz reply sudhanshukumar08@yahoo.com

2328


what is SIL 1 2 3

2014


How to Calibrate Coriolis Flow transmitter in field

1246


what is easiest way to read STL language in PLC?

3117


plz send me general of ongc

1941


line up procedure for dp type flow transmitter?

1885


What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?

3440


full process of gas turbin?

2080


Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability

1815


Why all the drains(Gland sealing,ESV,Casing inlet etc) are directly connected to the flash tank instead of hotwell of the condensor in the power plant? My Email Id:naba02222@gmail.com

2274


Any body have know try work calculation ???

1413


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

2182


which processor is used in dcs.

2237


Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?

914