Answer Posted / thomas
'Surging' is defined as 'A momentary back-flow' through the compressor from the discharge to the suction. This can occur when the mass flow of gas to the compressor falls below a critical level with a high pressure difference across the machine. When there is not enough gas to replace that being pushed forward, discharge gas will flow backwards through the compressor towards the suction side. This back-flow will tend to decrease the speed of rotation while the speed controller will try to maintain the correct speed. The gas flowing backward provides more volume to the suction side and the compressor picks up and begins to push gas forward again. The machine speed will tend to increase and the governor will again try to maintain the correct, set speed. All of this takes place very quickly; the backward and forward gas flow together with the speed control action causes rapid fluctuations in the flow and pressure of the system. This 'Surging' in the machine can be very damaging to the compressor and associated piping and equipment due to heavy vibrations set up in the system. Generally, if the suction flow drops too low, a 'Low-flow Trip' will shut down the machine. Also, surging can cause the machine to 'Overspeed' before the control system can react. This can also cause damage and is prevented by an 'Overspeed Trip Mechanism' which will again shut down the machine.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is hp & mp seperator .& what is its working principle ?
What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?
What is the purpose of LO Overhead tank in turbines.
OBJECTIVE TYPE QUESTIONS OF ANALYTICAL INSTRUMENTATION
How to Calibrate Level Troll in field
i want to find out iffco get test paper
can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.
Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell
what is use of communication wire in multipare cable(oil and gas field), why this communication wire not used in single pair cable?
WHAT ARE THE INSTRUMENTAL DIAGRAMSOF VALVES?
1.what is the power consumption of three element drum level control in sugar industries? 2.how to reduce that?
Explain the combusion chamber
HOW TO CHOOSE FREAQUENCY IN FMCW TYPE RADAR INSTRUMENTS. DESIGN BASIS OR DESIGN CALCULATONS ?
what is the working principal of pribe
How to work temperature gauge?