Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is over frequency protection

Answer Posted / aditya

over frequency occurs when the RPM of prime mover goes above the rated speed. This protection is basically for prime mover and gives a trip signal to the prime mover in case of overspeed so that the centrifugal forces dont damage the prime mover and alternator rotor. This is generally a result of faulty speed governor or sudden throw off or throw in of large magnitude. In addition overspeeding will also result in increase of supply frequency. certian electronic equipments are very sensitive to freq and get damaged hence over freq protection is given.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what do u understand about FACTS? how they are useful?

1973


If Dg set load increase 25%, How much increase fuel Consumption (15 kva 2 cylinder DG set)

2243


Define conversion efficiency of a power amplifier.

1226


A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.

1089


What is the function of NER and NET?

2426


IF HT CAPACITOR IN ON POSITION IS THERE ANY LOSSES I.S I SQURE OCCURS IN THE SYSTEM

2144


What is the general system requirement of alternator?

1830


how can we change the polarity of Alternating current rapidly? how frequency of ac can be controlled and changed easily?

2009


How to test IR testing & magnetic balance test

1984


hey guys i scored 910 on GRE and 67 on TOEFL respectively.I have an aggregate of about 74%in my B tech.For which colleges should i apply for an MS program in electrical engineering.I am looking for colleges in NJ,SC,NC,GEORGIA, NY. Please reply with a good response.....

1942


what is differnce btwen lll and lllg faults

1994


Why MCCB is Getting tripped sometimes when there is no load in the Midnight ?

1959


Will any motor burn if voltage provided is lesser than the rated voltage???? If yes, then how is speed control possible with voltage control

2148


why servomotor motor? where i apply for best output?

2024


how calculated Transformer losses.

2010