Why motor initial starting current is high?
Answer Posted / ganesh
why we can use power electronic devices in power systems
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour
Difference between On Line capacitor and Station Type capacitor.
How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?
What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation
What is the transfer function?
can i use 2000/5A Clamp meter to measure HT cable
why i can not use thimble on capacitor duty contactor
Mention the disadvantages of low power factor? How can it be improved?
In cable sizing calculation (determining the max route length of cable) why we choose the shortest length between cable length of full load current Iflc & starting current Istart?
when the Transmission and Distribution network where is the "feeder" lines are located? and why should be used in T&D network.....
11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?
What are the main parts of central chiller plant? Explain the function of each stage.
internally connection of photvoltic module
what is upper impedance and lower impedance of a distance relay