What is the harm if we install primary side 11 KV VCB at a
distance of one Km from the 11/3.3KV 12.5 MVA transformer
through 11 KV cable.
Answer Posted / rednaxela
it will damage the device if the system encounter electrical fault.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
How to calculate Voltage regulation of 22 KV Over head Line.
How to calculate cable size in HT AND LT
some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?
In a Impedance Based Distance Relay (Quad Characteristics) - Could there be two different Line Angle(RCA) for Ph-Ph & Ph-Gnd? If So Kindly Let me Know.. Where, What are the advantages of the same?
What is the difference between in Fourier series and Fourier Transform. and please tell me the difference between both of them and the why we use them in communication system?
How to dimensioning SDCCH, LAPD and CS7 signaling on GSM?
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
Is electro plating what type of load whether resistive, inductive or capacitive loads
why they were using TRIAC instead relay in some controllers and what is the advantages.
which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?
What is the difference between Generator Differential Relay and Transformer Differential Relay?
what is the meaning of the symbol << >> put in transformer drawing
why we r not earthed Control cable of C.T. terminals
what are the available sizes of pin type terminal lugs in the market today?