Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we not use the impedance relay in protection of short transmission line ?

Answer Posted / pritish

in case of short transmission line, the protection due to arc resistance is the major factor. hence , the relay should be selected which is less affected to arc resistance. and according to R-X diagram of impedance and reactance relay, the area of reactance relay is more and it is less affected to arc resistance fault but impedance relay is moderately affected due to arc resistance. so reactance relay is used in a short transmission line.


for more clarification, please email to pritish.nath@gmail.com

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear Sir I am living in Jaipur Rajasthan  now I did complete my b tech degree in electrical engineering in 2012  Sir how I gate certificate of competency for electrical supervisor

2046


it is possible to rotate the DG engine dc starter with wrong polarity connections? why?

2309


How many types are using in 220kv/400 kv swith yard

2236


Define phase lag and phase lead?

1190


Why we specify TNC switch with 1NO 1NC ,2NO 2NC ? how we get connection.?

1824


Define super node?

1256


why servomotor motor? where i apply for best output?

2086


reason of diode failure in alternator

1917


what is strip power factor?

2223


Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!

2139


can we synchronize star system generators with delta system transmission line ? and how ?

2880


What do you mean by power transformer?

1144


where does 22kv line starts

3149


Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?

1970


orifice sizing how done, checking & selection

2018