what effect on electrical equipment if PF is gone over 0.996
in leading when provider say that its keep in minimum
0.996lagging
Answer Posted / varaprasad inavilli
Electrical charges will be more
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
use of PIR in ehv breaker
Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.
How to calculate fault level of 11 KV system
what types of cable used in underground coal mining?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
what is the maximum temperature rating of a thhn insulated conductor?
advantage of motor design on higher power factor . normally motors are designed for .8 power factor. what is advantage of designing at .88 power factor
What is the permissible limit of shaft voltage for 6.6 KV motors ? Why? Is there any standard is available?
We have given to 3phase supply to ups system & how can coming netural
ratings of lightning arrester
we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???
what is the solution for meger test failed the MV cable?
In the Variable Voltage Variable Frequency Drive, how the Voltage and Frequency varied ? Is it varied in the Inverter part of the Drive ? Please give us supporting document if any.
Please elaborate th´evenin’s theorem?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.