what is the temperature rise test? explain in brief.with formula.
Answer Posted / jithendra
Temperature rise test will done for electrical panels only
Injecting the Rated Amp's to the panel
for Example:
4000 amp's panel rating the load set to 4000 Amp's the temperature is calculated
the Quality of the BUS BAR is known
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is saturation kit?which use above 15 kw motors panel side.
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
when will be the iocl interview results ifaced the interview on september 8 th
If breaker is undefined position, first step to do.
Explain what is rated speed?
What is the Surge suppresor? Why using in a UDB's and How it works?
Explain and give me an example of a time when you had to explain some new procedures to your co-workers for quality service delivery, how did you go about it?
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this
What is PQA???Applications........
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
what parameters should we check to reduce the power bill
How to measure power in 2 or 4 or n phase circuit? Please give me a formula.
what is mean by D.O. in distribution line poles?