Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1.what is the difference between MPCB and MCB ?
2.what is the difference between MPCB and MCCB ?

Answer Posted / saroj kanta nayak

1.Both MCB and MPCB protects against Short circuit and Over load. But MPCB is better for the more starting current taken by Motor. and the Current range can be ardjusted. In mcb we cannot ardjust the current.
2.Both MPCB and MCB protects against Short circuit and over load. But the main difference is MCCB have NO & NC contact built in which used for the control circuit. untill and unless MCCB made on control circuit cannot made on(for motor starter feeder) In camparision to MCB, MCCB have higher current rating. And if current rating increases ACB(air circuit breakers used).

 So in conclusion All MCB,MCCB & MPCB gives the same protection even can be used in any others place. But MPCB is best for MOTOR protection as it have Inbuilt OVER LOAD RELAY and current range can be selected. Others(MCB&MCCB) may give trouble of unnecessary tripping during starting of motors.For short circuit protection all devices like MCB,MCCB&MPCB functions similar way.

Saroj kanta Nayak
SIEMENS LTD.
KALWA,MUMBAI
Masters In technology from
Nation Institute of technology, Silchar.

Is This Answer Correct ?    30 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if sf6 gas low in gis what will happen

767


what does a string of resistors in a series will do?

1172


what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??

9393


We need to current density & short circuit calculation at 65kA for aluminium & copper busbar.

1678


What is the unit of magnetic flux density?

1114


what will be d.g. capacity to cater together for 14hp A.C. load & 3kw lighting load

1943


Why earthing is necessary for any equipment?

1651


How to calculate the multiplying factor for energy meter with ct ratio given

1961


The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?

3602


what is meant by class 1 E in electrical power supply?

2024


What does the kvar means?

1132


what is the formula for calculating the phase clerance between two phases and phase to earth how to calculate the cable for a motor

1950


What is the difference between security constraint unit commitment and security constraint optimal power flow?

1658


How harmonic block test are conducted on relays ( Siemens,Areva ect )power transformer using omicron kit?

2206


My load is 1635 KW. & current pf is 0.884, I have to improve it for 0.99.Please suggest what KVAR value is needed?

1551