What are linear elements and non linear elements? and I don't want answers with graph related
Answer Posted / n panja
Linear element are those elements whose voltage current relationship is linear. For example voltage-current relationship of a resistor is V=IR, which is a linear equation. Similarly for an inductor the relation is V=L*dI/dt, which is again a linear differential equation. So these are the examples of linear elements. On the other hand diode, transistor have non-linear voltage current relationship, so they are non linear elements.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Explain the experiment on ward leonard method of a speed control on a dc shunt motor with an suitable circuit diagram.
What are diffrent type of road taxes?
Is potential difference materials property ..? if yes tnen how.. explain brifly.
A ray hit a smooth regular surface at an angle of 20 from the normal. Calculate : 1. The angle btw the incident and reflection ray. 2. The angle of deviation.
How to decide no. of Step and Kvar for APFC Panel 40 kvar MD: 33.12 KVA Avg pf : 0.8540
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
DEFINE BREAKING CAPACITY OF BUSBAR & HOW IT IS CALCULATED?
Can we convert off line transformer to on line transformer
what is KA rating and how can we choose switchgears on applications
Which motor will you choose which can operate in both lagging as well as leading power factors?
What is the maximum operating temperature for a thermoplastic insulated cable?
which type of stability limit is higher,steady state or transient? why?
what is the acceptable limit value for Desolve Gas Analysis/
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
what is the electrical?