Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

sir, plz tell me how much kvar capacitor required for 1000
amp or 500 Kw load ? what is the formula ?

Answer Posted / waqas ali

in case,,,, tan phai 1 is not required???? give me a answer?

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between dry and wet type of 132kV terminations. which one is durable

2006


how is positive, negative, zero sequence is happen.. how is effect on 3 phase system

1808


54 Comments Alok and Bhanu play the following min-max game. Given the expression N = 38 + X*(Y – Z) where X, Y and Z are variables representing single digits (0 to 9), Alok would like to maximize N while Bhanu would like to minimize it. Towards this end, Alok chooses a single digit number and Bhanu substitutes this for a variable of her choice (X, Y or Z). Alok then chooses the next value and Bhanu, the variable to substitute the value. Finally Alok proposes the value for the remaining variable. Assuming both play to their optimal strategies, the value of N at the end of the game would be?

2191


if we have 320KVA Genset kindly advice how much load we can put it.

1531


I WANT HOW CALCULATE TO CABLE FOR WELDING PLANT ?

1838


What is the need of generator relay panel

2104


why we change the direction of winding in rotor ?how we make the north and south pole?

2063


I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

4037


what is the reactance,capacitance & impedence electrical armoured & unarmored Cables.

2206


If rotor works in clock wise what happens

1911


what is conductor copnstant of ab cable

1905


What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.

2367


What happen if we apply square wave or traiangular waveform voltage to the transformer primary winding instead of sinusoidal wave?

2170


The 3 phase Delta connection RB=440V, BY=350V,.......* is Line to Line voltage RY= ? And Formula....?

1716


Difference between RCCB, RCBO and ELMCB.

4092