why should a transformer be never connected to dc supply
Answer Posted / bapan
If Dc supply is given to atransformer there will be no change in the flux with time.so,there is no emf induced in the primary and secondary winding and hence transformer action will not take place.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
I want d.g.set our company
54 Comments Alok and Bhanu play the following min-max game. Given the expression N = 38 + X*(Y – Z) where X, Y and Z are variables representing single digits (0 to 9), Alok would like to maximize N while Bhanu would like to minimize it. Towards this end, Alok chooses a single digit number and Bhanu substitutes this for a variable of her choice (X, Y or Z). Alok then chooses the next value and Bhanu, the variable to substitute the value. Finally Alok proposes the value for the remaining variable. Assuming both play to their optimal strategies, the value of N at the end of the game would be?
Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC
sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.
Wind mill
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
how cables go in and come out for distribution from the feeder pillar box?
What is the function of auadag in a cro?
In Power cable specification what is U0/U and Um.
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
what is earthing.how we make it,describe briefly.
12.5 tons a/c is their how much kva generator can recommend to the customer.
For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?
What is the difference between in Fourier series and Fourier Transform. and please tell me the difference between both of them and the why we use them in communication system?
checking procedure of capacitor based motors.used in fans etc?