Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the List of Equipments, Instruments, Components
required in Transmission of electricity from 1 substation
to other substation(The equipments required in substation
too)?

What are the differnt IS standrds used for above equipments
in Industry?

Answer Posted / p. naveen kumar

Transformer, CT, PT, Lightening Arrester, CAPACITOR BANK ,
DC BATTERY, ISOLATORS, BUS BAR, EARTHING EQUIPMENTS, CVT,
RELAYS, FIRE FIGHTING SYSTEM THESE ARE USED IN A SUB STATION.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.

9656


what is the difference between the characteristics of two different phase bushing of any transformer

1854


When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?

2058


Mention how NPN and PNP transistor works?

1360


how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.

2478


Which are resistive loads & which one are inductive loads : Refrigerator, Split air conditioner, ceiling fans, well pump, fluoresecent bulbs, T.V, CRT Monitors, Adsl Routers, C.P.U, Printers, Deep Freezers, Speakers, DVD Players, Microwave oven etc. ? Output Power for these Appliances Would be same like this : P = V * A * P.F Or would be changed ? thanks

4036


which network topology offers the greatest level of tolerance?

2232


how to protect motor in dol starter having capacity of 30 hp.40 hp?

3254


dear sir/madam i want to get some knowledge about RRB EXAMINATION(section engineer) 1- what is minimum cut off 2- wht portion is major portion . 3- can any body provide Sample paper. thanks & regards ashish

2416


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

2009


How much load can be taken for chiller from 1500 kva transformer

1327


describe the Operation of induction generators from bus bars

2380


what is the effect of vector group while phase sequence of a generator changes,whether the vector group changes or not

2176


Starting times for soft starter & power factor is thier any standard or datas available in manufactures list. Kindly suggest.

1976


What is inductance?

1278