Differnce between earthing and nuetral
Answer Posted / dinesh
Neutral is a star point in a three phase system & earthing
is a low resistance path for current flowing for tha
protection of equipment & human body
Is This Answer Correct ? | 8 Yes | 3 No |
Post New Answer View All Answers
How to determine stage of Automatic Power factor controlling Relay(Apfcr)?
When steam condenses and becomes water at the same temperature, the specific heat for the process in kJ/kg k is
What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?
What is process of anneling transformer core
circuit diagram of trip circuit supervision relay
How to calculate VCB rating for 33KV ,25 MW Power line?
which protection function should measure RMS value of current&DFT value of current?
What is rotary phase converter?
WHaT IS THE CONCEPT OF INDUCTION LAMPS IN MODERN LIGHTINGS, and HOW IT WORKS TO EMIT LIGHT ( AS NO ELECTRODES ARE PRESENT ) ?" COULD INDUCTION LAMPS CAUSE INTERFERENCE WITH COMUNICATIONS INTO A STORE USING INDUCTION LIGHTING ? WHAT IS THE BENEFIT OF USING THE LOW FREQENCY INDUCTION LAMP , VERSUS LED , AND VERSUS FLUORESCENT, AND VERSUS ANOTHER KIND OF LIGHTING . THANK yOU MOISES GUINDI
i have to install a HT panel, what components, I have to use in this and what will the diagram of that diagram,please tell me each and everything.
what is a composite error in current transformers, why occurs & in which it will occur i.e, either metering ct/ protection ct
I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.
where are the circulat the diesel in DG parts name with pictue
what happens if earth of 33kv cable is not connected to earthing pits? please send this query's answer to ngrm.sudha249@gmail.com
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?