HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME...
SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,,
I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION ..
ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT
REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY
MANIFOLD..!!!
BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV
IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 ,
SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN
THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER
THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO
ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK
LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR
CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT..
THANKS YOURSSSSSSS
Answer Posted / carl_ellis
There is insufficient information to determine what the
correct range of the transmitter should be.
1) Is there a capillary with remote seal on either side of
the DP xmtr? If so describe in detail.
2) Is the DP xmtr mounted directly on the lower flange? If
not how high above and below the lower flange (tap) is it
mounted?
3) Is the DP xmtr high side connected to the lower flange (tap)?
4) Is the low side a dry leg or wet leg?
5) What is the specific gravity of the material in the tank?
6) If the low side is a wet leg, what is the specific
gravity of the fill fluid in the wet leg?
7) What is the elevation distance from the lower flange and
the maximum level?
8) what engineering units are used for level ? mm H2O?
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How to fix back the valve actuator stem
what is the difference between scaler and vector drive
hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.
i am having information technology branh ....... can i prepare for psu exam
how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.
how many type of plug are used in pneumatic control valve,name them.
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
Why grounding is necessary? Give example with diagram.
Please tell me details about Sox,Nox,SWAS analyser????
how can leve transmetter calibate in feild .and also put cv and flow plz .....
please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
What are different types of orifice plates? State their uses.
What is the use of control cable?
what is your eligibility criteria for freashers?