Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What kind of maintenance is conducted for generator

Answer Posted / ramesh

1. Daily maintenance - A check
2. every 250 running hours check - B Check
3. every 1000 running hours check - C check
4. Every 3000 Running hours check - D check
5. Taphead checking at 5000 to 6000 running hours - E Check

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

tell me about eletrical contractor

1995


what is meant by directional earth fault and non directional earth fault? describe both.

1942


How much ph is maintained of water resistance starter for slipring induction motor ?

2458


WHAT CAUSED THRESHOLD VOLTAGE TO EXIST?

4113


HOW DOES THE ELECTRONIC ENERGY METER WORKS?

2214


Sir pl provide 5 year sample paper for post junior engineer(electrical).I have currently applied for junior engineer (electrical) on RRB Ajmer

3689


what is the AC Plant and how can do the work with parts and picture tell us 150 Tr

2093


Give some example of fault limiting devices?

1426


what is the role and fuction of automatic transfer switch in rotary ups

1992


What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?

3993


limitation of conductor height on ground when we consider EMC

2090


What types of question are done for diploma students in aptitude test

1715


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2244


full form of electrical?

2780


100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.

2424