What is the proportioning by weight of 1:2:3 concrete mix
design of cement, sand, gravel, and water in metric for a 3000
PSI concrete strength and a target slump of 75-100mm?
Answer Posted / awadhoot
3000 PSI concrete strength equals to 20 N/Sqmm.
characteristic compressive strength of concrete.
Now refer to Table 9 "Proposrtions for Nominal mix
concrete", on Page no. 23 of IS 456:2000.
Here, for M20 grade concrete, the total quantity of dry
aggregates by mass per 50 Kg of cement is given as 250 Kg.
Considering proportion of fine to coarse aggregates as 1:2,
Fine Aggregates can be calculated as 83 Kg. Say 100 Kg, then
coarse aggregates will be 150 Kg.
Quantity of water per 50 kg bag of cement can be allowed up
to 30 litre to the Max. However, target slump of 75-100mm
can be achieved by following trial and error method.
Hence, for 1:2:3 proportion of concrete,
Cement:Fine Aggregates:Coarse Aggregates
50Kg : 100Kg. : 150Kg.
Here Fine Aggregates = sand and
Coarse Aggregates= gravel
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
Analyze the rate for 1st class brick work in superstructure with 1:6 cement sand mortar. Consider 1000 cu.ft quantity and work out the rate per cu.ft
Before casting a basement roof slab which is connected with retaining wall surcharge load (i.e. sand or earth filling) outside the retaining wall is prohibited because of––
in 100 cft = 1350 bricks in 100 cft = ? bloks
How Can I know the wastages(%) of each work added in estimating the quantity of construction materials?(Eg. Ceiling Work, Brick Work,etc....)
What is the general specifications of a bituminous pavement road?
to draw bm diagrams for portal frames under different loadings//
what is pile and deam foundation
What is the biggest dam in america?
undistributed samples are obtained by
how to calculate the density for high density concrete ? or is it same as the density of RC?
Explain the different types of building contracts?
How to calculate Acctually Brickwork Quantity in Honey Comb Brick in circular Soak Pit
how do i remedy a foundatiom that the column bases was cast and aftet 28days crushing the conprehensive strength of the concrete fall below the specification 25N/mm2
what should be RCC material i.e iron rod(mm)x cement x stone x sand for laying of slab L 42'x B 22'x tk 0.375ft = 1nos & column of H 17'x15"x8" 2nos.
what are the layers of the national and heir aprox thickness??