How much area is covered by a single lightning arrestor to
protect object from lightning strokes ?
Answer Posted / rajesh verma
The area covered by the lighting arrester depends on the
manufacturer specification and design. it can be 75 Mtr to
250Mtr
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
What is big transformer parts and their function ? Ty
Hi, This is Laila. I am selected for syndicate bank interview. Could you please share your views and the questions asked if you have faced the interview My email id is laila_honey09@yahoo.com Please send as fast as u can.Thank You Thanks... Laila.
How much ph is maintained of water resistance starter for slipring induction motor ?
Which device of PlC does share load between DG sets when DG are running in perallel?
what is the size of cable for 15kw motor and 85 meter cable length using with vfd
What is the temperature PROFILE OF A FLUID W. R. T. Distance from a sphere to which it is IN CONTACT which is at constant temp.?
Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?
In what cases (circumstances)we should apply P controller, PD controller, PI controller & PID controller ?
At what factor resistance r of a conductor depends?
what are the applications of TIG welding
how to get electrical supervisor competency certificate in gujarat. i did 3 year diploma in electrical
Is it possible to obtain 480v or 550v in single phase output by giving the input to 230v to a single phase torodial type transformer without using a stepup transformer?
Explain with example of functional requirements of protection relay in terms reliability, selectivity, sensitivity
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what ispositive, negative, zero sequence impedence?