Difference between ultrasonic flow meter and radar type flow
meter
Answer Posted / carl_ellis
Difference between ultrasonic flow meter and radar type flow
meter
That's easy. Radar (radio frequency) energy is not widely
used, if at all, in commercial industrial flow meters.
Commercial ultrasonic flow meters use acoustic energy above
the range of human hearing to measure flow velocity of
liquids and gases. The measurement is inherently a
velocity measurement.
Transit time technology for liquids with no suspended solids
or bubbles, or doppler technology can be used for liquids
with suspended solids or bubbles. In-Line transit time
ultrasonic is accurate enough to be used for custody
transfer. Doppler has limited accuracy.
Carl Ellis
Measure First
Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
How ejector(or)evactor air pump is working in thermal power plant?
what is difference between fork type and capacitance type level switch. where it is using
how many pulses are required by a ac induction servo motor of 4 poles with 50 Hz frequency to rotate by 1 degree?
What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
What is the working principle of the magnetic meter?
What is Erosion in a control valve?
how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744
How does work A temperature valve or fv control valve in process plz brief me
Name different parts of a pressure gauge. Explain the use of hair spring in the pressure gauge.
What is Span Error
If fire would be inside the plant which fire detector is to detected the fire.
in sulfur process what is material of impulse line we use to connect with transmitter ? and does teflon affected by sulfur?
In apron feeder how TPH is calculated?