Why birds seating in HT line does not get shock?
If person hangs in HT line (single hand or both hands) does
he get shock?
Answer Posted / shafiq dhaka
birds don't get shock because the length of bird's body is small. If a human touches the H.T line then he get shock. Bcz human body is
Variable registance. There will be potential difference betwen touching point and lowest point of the body. And shock level is depend on length of the body. For exampl, if a man body height is 2ft he will get less shock(it may cauz to die) but if body height is 6ft then he will burn. Thats y H.T line workers use special gloves though they touch live line from helicopter.
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
model question paper for supervisor trainee
Why wind turbines wheels rotate constantly
Why PT voltages are measured with respect to ground? What do u mean by voltage or current polarized.
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
how to design step down 12 V, 1mA small transformer from 220 V AC? Because according to VI relation and power transfer it results bulky...
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
Why Neutral Isolation is required?
What is the minimum distance to be maintained in between HT panel and LT panel and Instrument panel as per IEC and NEC standards?
I need a formula to calculate the size of cable as per load but in the terms of length. Please Reply me as i search lot of sites but i did not get the answer.
What is the difference between acs 550 & acs 850
If SFU is Switch Fuse Unit, What is the expansion for FSHF in Electrical Engineering?
transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?
WHY MOSTLY Rph IS USED FOR CONTROL CIRCUITS AUX. SUPPLY ?
What is the IS standard for MCCB to be use (As per capacity of AMP)& for ACB also.
What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.