What is the frequency of dc current????

Answer Posted / fazul

voltage is constant for dc supply.
hence current is also constant for dc supply.
hence the frequency of dc supply is zero.

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT CAUSED THRESHOLD VOLTAGE TO EXIST?

3518


Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?

1021


why Current is lead 90 degree and voltage is lag 90 degree in a capacitor.? why Current is lag 90 degree and voltage is lead 90 degree in an inductor.?

1787


sugest any typical project ?

1369


What is the temperature PROFILE OF A FLUID W. R. T. Distance from a sphere to which it is IN CONTACT which is at constant temp.?

1629






What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.

1950


300m long and 30kw inductive loade 3phase supply how many size cable required

998


There are a trformer and an induction machine. Those two have the same supply. For which device the load current will be maximum? And why?

674


What are the different methodes for calculating the short circuit Current?

1499


Why the symbol of register is "zig zag"

1131


When will you multiply and devide with derating factors to the actual value while sizing the cable?

1487


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1358


What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.

7377


which network topology offers the greatest level of tolerance?

1573


what happen if the parallel generator phase angle shift by 1 degree in manual mode

1560