Answer Posted / jerry smith
Gas and Steam Turbine Basic protection include:
Overspeed, high vibration, Low lube oil pressure, and high
lube oil temperature.
Specific to gas turbine would be high exhaust temp, excess
spread of temperatures in the exhaust, inlet suction low
pressure, combustion pulsations, compressor bleed valve not
closed, underspeed too close to surge point, fuel valve not
in proper relation to turbine load, and flame detector
failure.
Specific to steam turbines would be inlet steam temperature
high or low, inlet steam pressure low, exhaust steam
pressure high, exhaust steam temperature high, drum level
high on the supply boiler.
Generator faults do not always trip the associated Turbine.
| Is This Answer Correct ? | 9 Yes | 0 No |
Post New Answer View All Answers
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
How to calculate power press toneage
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
How do you consider that you can improve and what assistance do you need to achieve this
why airtel use + 24 volts and other operators use -48 volt
can dp type level transmitter work in under vaccum condition
what is the trip circuit supervision in an electrical meaning?
what is the basic use of power plant in equipment
What is difference between secondary Air & Tertiary Air and Their use.?
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
operation
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
How We Calibrate the vaccum transmitter?
What is LB-SR.
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?