Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is an isolation transformer??? what is its purpose???
what happens if it is not used where it should be used?????

Answer Posted / rajesh.b.jadav

Yes, Isolation Transformer has same ratio its used for
protection of equipment against current leakage if we do
not used than if leakage happened in other equipment than
it will be affectred all equipment connect with same supply
and if we used isolation transformer than equipment
received supply from isolation transformer not effected
with leakage which happened in other equipment.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.

2055


What happens if we run alternator on under frequency? 

2048


what is the current setting for different relay protection for transformer .

2230


what is counter poise conductors

2100


What is the formulae of Megger value for a A.C.Motor

2812


A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.

2988


CT Ratio of a energy meter connection is Red Phase : 100/5A, yello Phase : 50/5A & Blue phase : 100/5 A what is the overall Multiplication factor

1601


Tell me the reason of connecting domestic t/f primary in star or delta,and also secondary side.

1917


how to test reverse power trip?

4414


how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids

1845


What do you mean by phasors?

1018


What descriptive information does the NEC require to be marked on all conductors?

1950


what is package substation.how many types they have

2055


how to generator maintenance (A Check, B check,Etc)

2250


What is oscillator circuit?

1080