Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the cube depth is 150 mm which is used for testing

Answer Posted / vinoth kannan

Basically, the force supplied by a concrete compression
machine is a definite value. For normal concrete strength
application, say below 50MPa, the stress produced by a
150mmx150mmx150mm cube is sufficient for the machine to
crush the concrete sample. However, if the designed concrete
strength is 100MPa, under the same force (about 2,000kN)
supplied by the machine, the stress under a
150mmx150mmx150mm cube is not sufficient to crush the
concrete cube. Therefore, 100mmx100mmx100mm concrete cubes
are used instead to increase the applied stress to crush the
concrete cubes

Is This Answer Correct ?    14 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Requirement of cement, and steel 1:2:4 ratio concrete in 1128 Sqft area(Cement No of bags, steel in Kgs)

2007


In foundation design, while we do the base pressure check, we normally check if the attained pressure value is less than the GROSS BEARING CAPACITY of the soil which is the sum of net bearing capacity of soil and the overburden pressure. Actually, the overburden pressure acts against the net bearing capacity of the soil and I feel that we are actually increasing the bearing capacity value and doing the check. I feel that this is NOT right. Please clarify on this.

2269


specifications of fe500 steel

3538


what is the difference between prime coat and tack coat in road construction

5040


Explain what is Hybrid Foundation?

1175


explain the rale of the government in the construction industry

2400


what is meant by residual strain?

2373


what discoveries did you have in relation to your course?

2144


What is the use of extend command?

1294


what is the use if we fixed butterfly ties in column and masonry work joint?....where we have to fix(distance)..

2507


Dear Frds, How can i calculate the Steel for RCC Slab, Please provide one Example also, so that i can understand very well. Ex: Area: 1320.0 Sft.(44' X 30') Span: 15'(Default). Column Size: 9"X15"(6 No.s 12mm Rods) Please Provide Calculation Details. Thankyou. Satish

2638


I am a civil engineering student and going to attend interview in this week in an IT company.Will they ask me questions about my area of interest or cs

2550


WHAT GOAL DO YOU HAVE IN YOUR CARRIER?

2433


what is the hanekom repairing material after concreting work

2412


Explain what are the problems one might face while having a Cantilever balcony?

1326