Hydro P.P. run @ 600 rpm,8pole, Nucler P.P @ 1500rpm 4 pole ,
ThermlP.P @ 3000 rpm 2 pole.Why this diffrence??? when we can
generate electricity @ 600 rpm then Why we had incresed speed
in NPP & TPP???

Answer Posted / nirav patel

@ 7anoter4 thnx for your complement.

weight,dimensions,price decrese as decrease pole i agree. but howmuch???for genereation in higher rating continusely these points are not such a big problem.

we have 2 burn more coal or any fuel to get more speed like 3000 rpm with comparison to 600 rpm.

And my question repets here....

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to Prepare preventive maintenance shedule of machine tool.

1521


what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?

1993


Ceiling Fan and Storage type water heater. Discuss

1547


Safety of dry type transformer

1486


1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?

4222






in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?

1412


What is proportional controller?

696


how can we understand that where we have to use ac or dc coil for solenoid valve and why?what is the different between coil of ac and dc explain please.

1492


I am EEE student i want to improve my core side skills.how cn i approach it?

1986


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1362


Why High voltage are generate noise ?

957


what is Anti-pumping?

1498


where does 22kv line starts

2666


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1405


how is the incoming cable size calculated for a given current rating of a panel??

1432