Hydro P.P. run @ 600 rpm,8pole, Nucler P.P @ 1500rpm 4 pole ,
ThermlP.P @ 3000 rpm 2 pole.Why this diffrence??? when we can
generate electricity @ 600 rpm then Why we had incresed speed
in NPP & TPP???
Answer Posted / 7anoter4
The synchronous a.c. generator rpm[rotations per minute]
depends on the mechanical drive rated rpm –Diesel Motor
could be high speed –for 60 Hz systems up to 1800 [I did
not see 3600] and the lower limit may be 100-150 rpm.Low
speed D.G. consume per kwh is lower so for 40 years will be
a huge advantage.
The dimensions [and weight] of the motor-and of the
generator too-decrease as the speed increase [and the price
also].The turbo-generator is 2 poles generator usually as
this is the minimum equipment and installation cost.
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
show the single line diagram of star delta starter with single phase preventer
Explain the fundamental difference between emf (electro motive force) and pd (potential difference) ?
What are the basic & Majour problems in UPS ?
take 100kva DTR( delta/wye ), what ll happen if we connect 11kv to LT side instead of connecting to HT side? will the DTR behave as a step up transformer or something else????
What are protections for dty type transformers
what is the difference between delta delta and star delta connection transformer? why we use delta delta transformer since it need earthing transformer for grounding?
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
whether starting current is limited to rated current of motor through soft starting or it exceeds the rated current?
does buccholz in a transformer use batteries
HOW WORK HEAT PLATE EXCHANGER
WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION
in my working site. momentary jerck in electrical supply ocurred frequently which cause of multiple losses in our electrical equipements. how can we protect our electrical machines and equipements in this situation.
if we apply 1000ADC instead of 100ADC or We apply 50ADC instead of 100ADC,What will be happened in the test result value.Pl explain
what happen when power factor of 2 parallely operated transformer become equle?