What is the use of conservater, bucchos relay, breather in
a transformer?
Answer Posted / rajput deepak
# 6 Bucholz relay is the protective deivce which protect
the
transfomer from overload,overheat,short ckt protection.
when ever any over load or short ckt happen ,the first
thing increase which is temp of transfomr and this relay is
connected with temp sensor controller and these realy has 2
NO contact first alarm contact and another is tripping
contact.
breather as name indicate ,when the temp of oil get
increasing it expand and Dry air of conservator tank goes
out,after cooling the oil ,again conservator tank need Dry
air ,which is supplied by breather and silica gel takes out
the moisture from this air.
conservator tank is stored the cools oil.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What should be the values of settling time, peak time, steady state error, overshoot, rise time, MPOS (Maximum percent over shoot) to keep the system in transient state, to keep the system in steady state ?
In which of the following case, the rotating magnetic field is reversed? A regenerative breaking B plugging C dynamic breaking D forward motoring
will there be any problem by recovering slip from single phase induction motors?
What are the three major categories of error?
Hello seniors m an engineering student in 3rd yr..i want to know what are the software course in electrical field?i wanted to do certification course but i dont know much about the course?..Regards
how we can calcultae the short circuit level for bus bar
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
is IS says that neutral should be brought to switch box. and this one is a recomended practice
CALCULATE THE TOTAL VOLTAGE DROP AND SELECT THE CABLE SIZE IN MM-SQARE FOR A PANEL-262KW AT 110 METER FROM THE SOURCE SUPPLY , SUPPLY VOLTAGE 240/415
What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
Explain Random and Deterministic signals?
sir pls tell me . our ct specifications are 120/5 ,2 core , 0.2 and 5p10 class , 30va and 30va buden. insted of 30 va i want use 15 va. can i use?
In CTs tan delta point should be earthed , what is the reason behind it?
What is meant by impedance? difference between high & low impedance ?
what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer