Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transmission voltage is 230kv and not 220kv which is a
multiple of 11

Answer Posted / seshagiri204

genereally in our India standard transimission voltages are 11,33,66,110, 132,220,400 and 765 kv . because generator rms voltage output is given by multiple of form facor 1.11

Is This Answer Correct ?    11 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is Servo Ventilated Motor?

2034


How much load can take a 16 mm aluminum cable 3 phase

1747


we have a rewind motor of 2Hp,2800Rpm, 220Volt AC. how can we choose the running capacitor for this motor, any formula for that?

1908


In ACS 1000 drive we are using 12 pulse converter,why don't use 3 pulse converter.

2013


EXPLIAN THE IMPORTANCE OF POLY PHASE CIRCUIT.

2161


what is different between phase and netural

1974


What is domestic transformer? Draw the connection of domestic transformer.

2304


If o/p power is doubled by how much does the sound increase

1082


if 3400kw slipring motor rotor shorting done and motor started on mv drive ,what will be the rotor shoring current

1698


what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?

1898


what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator

2032


Explain the purpose of inductor in an electric circuit?

1129


how to calculate distance between busbar supporters for LT panel, what are the factors influencing in this design

5312


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1648


Why the unit sizes of hydro generating machines are not standardized as in case of thermal powerplants?

1097