how many lab test
on bricks and
aggregate write
briefly please
Answer Posted / udhaykumar
lab tests for bricks :
a) compressive strength on bricks
b) water absorption on bricks
c) efflorescence test on brick
Lab tests on aggregates :
a)sieve analysis
b)flakiness & elongation index
c)moisture content on aggregate
d)aggregate impact value
e)aggregate crushing value etc...
for detailed answer www.buildtest.com
Is This Answer Correct ? | 12 Yes | 0 No |
Post New Answer View All Answers
at what pressure ply-wood is obtained by gluing wooden sheets
how can we calculate steel value, depending on load
How will be cutting in timber plate size 600*400 column size
how to take the quantity of block work and plastering 1block price:3saudi riyal cement:1bag:15 saudi riyal sand:3bag:20 saudi riyal 1mason:9hour per hour 40 saudi riyal 1labour:9hour per hour 40 saudi riyal can anybdy calculate
What are your future hopes for this job?
Why do you want to work here
Laying bitumen concrete 40mm thick using 0.1372 cum of 13.2 10mm metal ,0.2387 cum of 10 5mm metal...what did it means please explain me how much cum of 10 mm metal need?
Whats the meanig of ,'K' VALUE in the case of soil.....
Design a shear wall of length 4.20 m and thickness of 250mm subjected to the following forces.Assume Fck = 25Mpa and Fy = 415Mpa and the wall is a high wall with central part 3440mm x 250mm and two 380mm x 760mm strong bands at each end with following loading. S.No. Loading Axial force Moment Shear 1 DL+LL 1950 600 20 2 Seismic load 250 4800 700
a) Difference between Ghol , Chimney & fly ash bricks b)Floor to floor height is 3m , rise=15cm , tread 20 cm , how to design staircase means steps landing
100mm block work 64 bags of cement used 150mm block work 286 bags of cement used 200mm block work 20 bags of cement used patly work (M15) 293 bags of cement used mortar ratio is 1:5 how to calculate volume of sand in cum & no. of bags
In Residential home construct footing,beam, column,lintel,rcc roofs which dia rod used how to self assumed
Gave a cantilever beam with 3 legs.Told to draw the bending moment diagrams, axial force diagrams and shear force diagrams.From BMD he asked to show how the reinforcement will be provided on the tension side.
Design a reinforced concrete combined footing (rectangular) for two columns located 3.60 metres apart. The overall sizes of the columns are 40cm x 40cm and 69cm x 60cm and the loads on them are 1000 kn and 1500 kn respectively. The space available for the width of the footing is restricted to 180cm. The S.B.C. of the soil is 280 kn/mm2 use M15 concrete.
how we can find sieve #4 is 4.75mm?