Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN THE CASE OF AN ELCB, IF THERE IS ANY UNSTABILITY BETWEEN
PHASE AND NEUTRAL IT MAY TRIP. BUT MY QUESTION IS WHEN A
LOAD IS CONNECTED IN BETWEEN P AND N, THE LOAD CONSUMES SOME
POWER AND THERE IS A DIFFERENCE IN NEUTRAL WITH RESPECT TO
THE PHASE. THUS ACCORDING TO ME, THE ELCB WILL AUTOMATICALLY
OPERATES WHEN EVER THE LOAD CONSUMES-- I KNOW IT IS WRONG.
BUT THE SOLUTION IS?????????

Answer Posted / pillay

Maybe your understading of the elcb/ rccb is not true.Any load
consumed current is shared among the phases or and
newtral.that means what ever current that flows through the
elcb must flow out,there can be a difference only when there
is a loss, which means some of this current that had flowed
through are flowing out a different route,(leakage)if this
difference exceeds the trashold of the elcb/rccb than it
trips.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain the term parallel path in dc machin ?

2211


What is the difference between multimeter

1971


What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act

2032


How many types oil using in transformer ? How many letars using in transformer..?

2109


When will you multiply and devide with derating factors to the actual value while sizing the cable?

1945


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1920


what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer

2110


along with technical test papers

1608


What is the method of estamating of cable, CB,MCB ?

2174


What is MSL designation of a motor and same may be provided in details.

1715


explain safety measures in alternator?

1785


how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters

1610


Enlist four components of electrive drives.

1843


what are the effects when a salient pole alternator is run at high speed like 3000 r.p.m?

2429


how many joint can done in HT line and what is life of the joint

2234