Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why vaccum circuit breakers are preferred over m.o.c.b

Answer Posted / swetha

MOCB contains oil which expands and contracts during working which may create vacuum/gases inside the circuit breaker which may lead to an explosion sometimes if proper care is not taken.They also require a cooling system. Moreover, these circuit breakers require proper maintenance like changing the oil, taking proper predictive maintenance etc. But in the case of VCB's they don't require any maintenance, exhibit high arc quenching property, offer good amount of cooling. Hence, VCB's are mostly preferred.

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in indoor type circuit breakers why only the corner breaker trips specially during cold season. What is the reason.

1861


What is electrical grounding?

1144


what curve and rateing would you use for a three phase 0.75kw motor?

1970


how we can calculate the efficiency of a diesel generator ?

1683


Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?

2108


Why the output of OP-AMP is always less than Vcc?

1895


can we conduct the swineburne's test on a dc series motor? why?

2117


I use 20 nos led tube 4feet, in pathway 100mtr approximate, so what size cable i use for lighting

1445


What is cable tray, its type, and its support?

1138


Why do we use copper cable for HT Supply and why not Aluminium?

1997


Why neutral is not used in three phases dol starter

1927


Q) Write VBscript code along with QTPscript code in QTP tool for below scenario 1. Launch yahoo site(i know) 2. Do loogin(i know) 3.Click inbox link(i know) 4.Go to every page of mail box and count no.of read mails and no.of unread mails(i know) 5.Store page numbers, read mail count and unread mail count in a new excel file sheet 6.Create 10 types of graphs on that data 7.Do logout and close site(i know) 8.Save new excel files with graph

2482


How to set a Zone 1 distance relay for distribution feeder?

1995


We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.

1628


300m long and 30kw inductive loade 3phase supply how many size cable required

1412