Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

We have a Yokogawa Micro-XL DCS, which is having around 300 I/O, but whenever there is any wire gets grounded in field, the 24v supply to all loops gets dipped & all the indications at DCS goes to IOP(shows input open), at present we have fixed 500mA fuses in all the lines but which does not working. Does it required to replace with lower amps fuse, then how much or is there any other solution for this.

Answer Posted / dipankar layek

AT +VE END OF TERMINAL BLOCK USE 100 MA FUSE IN DI CHANNEL AND 50 MA FUSE IN AI/AO CHANNEL.
I THINK THIS WILL SOLVE YOUR PROBLEM.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

all questions related to instrument technician in any offshore oil and gas company.

21657


Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?

1779


the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove

1682


How r the calculation of process line mpm.

4777


why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature

1803


Speedtronic system .

1951


Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264

2381


what is loop1 and loop2 in MTS LT?

4639


Which language of programing is popular? how can i learn it ?

2129


why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?

2203


What is the use of gauge?

1109


what is 24vdc live and dry supply

2244


how will you segregate the alarm levels in alarm management system during factory Acceptance Test

2372


Boolean algebra

2160


If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?

2361