What is the difference between a Distribution Transformer
and a Power Transformer.
Answer Posted / hardik
basicaly we can used distribution X'mer which is DYN1
OR YYN1 what ever but degree 1 we can used for reduce
ferranti effect and also good for power compansation.
similarly DYN11 OR YYN11 anything 11 degree used in
distribution for reduce lagging power factor and also
compansation purpose.
This are main difference
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the polarization index value ? (Pi value)and simple definition of polarization index ?
what shall be no load voltage of 132/33 kV transformer ? is it 33 kv of 34.5 kV
i karmveer bharti persuing b.tech . plz send me syllabus and name of reference books. for preparation of section eng.
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
Explain few advantages of electric traction system?
Give details of your interested designation, the post you are interested to serve the company better and explain why you think you can serve the company better in such position if employed?
Hello seniors m an engineering student in 3rd yr..i want to know what are the software course in electrical field?i wanted to do certification course but i dont know much about the course?..Regards
State superposition theorem?
How to calculate the heat load for a electrical room
how to calculate transformer turn primary & secondary side 11kv to 420v
What are the basic & Majour problems in UPS ?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
what happen as when voltage drop(or may decrease) ? in case of atomic base theory?
how to select rating of HT Panel
How to setting the volume of RTCC panel AVR (11kv) controller