Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why is transformer connect parallel? why
not series? ....plz...

Answer Posted / karna

Transformer is a voltage source, So voltage source always
connected in Parallel, it not possible to connect in
series ...

Is This Answer Correct ?    5 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what happen if the parallel generator phase angle shift by 1 degree in manual mode

1981


i am completed diploma in ece,and working in ht and lt lines.so is elligible diploma in ece for get electrical C Licence?plse give ur opinion?

1831


How to operate a ac chilar plant?

2406


Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?

2045


substation+ plc system

2004


what is residuel magnetism. and how order lead acid batteries for 24 volt. emergency lighting system.

1934


What will be the current drawn by HT motor, if low voltage is applied.. any formula to calculate the LT amps of HT motor.?

1397


what should be the acceptrd value of winding resistance for 2.5MVA transformer

2263


What is the difference between cylindrical-type and sandwich-type winding?

1404


WHAT IS MEANT BY INSULATION CLEARANCE IN VACCUM?

1917


difference between semiconductor & conductor & insulator?

2326


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


Explain difference between stand by earth fault and residual earth fault protection?

1935


How to reduce the static electricity producing in solvent room? By P.D.Patil BioCon

2023


What is the source of dependent source ?

1822