why transformer ratings in kva?

Answer Posted / shanmukh

cu losses of a t/f depends on current and iron losses are
depend on voltages total losses depending on volt ampere but
power factor of a t/f independent of total losses because
t/f rating in kva but not in kw

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

design of IGBT firing circuit for 11KV

2096


Why LED light has advantage of rapid reflection ,although other lights alse reflect.? and this light is considered to be best for transmission usage in case of Free optics

1579


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1257


What are the functions of different probes used in cro?

673


if the armature current in a dc generator is ac ( sinusoidal ) why doesnt the sjhape af armature mmf a sinusoidal (ni) ? armature mmf in case of a dc machine is triangular.

1502






How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator

1606


Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT? 

1450


What is the effect of solar radiation on the design of an Isolated Phase Busduct?

1851


I am going to appear for the RRB Chennai junior Engineer online exam. Please send me the previous exams question papers (also solved) to my mail id: rrkhandhar@yahoo.com

1517


I want to know the 'Test voltage' for Tandelta testing of 3.3 / 6.6 / 11 KV Motors. Please explain

1783


Where voltage are high and current to be interrupted is low the breaker preferred is:

1775


In HI POT test what is reason for applying the AC VOLTS and DC VOLTS in different applications what is the nessesity for this ?

1445


why ups rating in kva? and why ups are in parellel?.why isolation transformer is used in ups?

1466


What is the minimum underground tank size capacity considered for firefighting purpose?

1466


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

1665