how can we calculate cutting length of a column ring
(300 x 600)
Answer Posted / md nahid akhtar
assume c.cover of column 30mm.
so, 2(L+B)+24D
where, D= dia of steel bar.
sol,assume dia of steel bar= 8mm
=2(540+240)+24*8
=1752mm.(cutting length for col ring)
| Is This Answer Correct ? | 10 Yes | 22 No |
Post New Answer View All Answers
A rock anchor 3 1/2” in diameter is placed in rock. The which has an allowable shear strength of 1200 psi. Determine the required anchorage length to safely carry a 80 ton load using a 2.0:1 F.S
Why is the use of granular sub-base in concrete carriageways not preferred, explain?
Why reinforcement done in shorter span in two way slabs
How many square meter can a worker/labor demolish a structure per day?
What ingredients with% found in ppc cement??
I have to conduct load test on greting cover, pressure gauge is in kg cm2, how to caluculate load on this greting cover.
i have to give lap joint fo 1Mtr steel of dia12mm,whenever i did mistake i cut less 5cm plz tell me how much i will give lap joint so that length comes 1Mtr
Curing time for 1)R.C.C slab 2)B.W 3)Plastering
Which code specifies the specification ofthe construction joints to be provided in the raft slab of a basement which is 6 m deep.what should bethe detail of such a joint?
What are the main reasons for conducting pull-out tests for soil nails?
Dear Sir I Mahesh C. Bhamre have already given a Exam for Superintendent Officer / Public relation Officer Exam Dharmday Aaukta held at Nashik on Date 29/08/2010. My seat no was 5040247. and my cell no is 9822677994. and my mail Id is - mahesh.bhamre@rediffmail.com So can you pl send me details of result of respective exams. Thanking you in Anticipation.
What are the types of slump?
what is directivity effect?
how to caluclate sienerge qty in construction in ap
WAP to print 1) 1 1 1 1 1 1 1 1 1 1 2) 1 2 3 4 5 6 7 8 9 10